TECHNICIANS' manual
- English -
37 di 52
7.7 Malfunctions and solutions
Problem Cause Action
NO MACHINE POWER
• The general switch is in the "OFF" position.
• The machine switch is faulty.
• The mains switch is in the OFF position.
• The wiring is defective.
• Place the main switch in the "ON" position.
• Replace the main switch.
• Turn the mains switch to the ON position.
• Check for any faulty connections.
NO WATER IN THE
HEATING UNIT
• The water mains valve is shut o.
• The cut-o valve of the automatic level device
is closed.
• The pump filter is clogged.
• The motor pump is disconnected or jammed.
• The water filling solenoid valve is faulty.
• The water inlet solenoid valve filter is clogged.
• Open the water mains valve.
• Open the automatic level device valve.
• Replace the pump filter.
• Check the motor pump.
• Replace the water filling solenoid valve.
• Clean or replace the solenoid valve filter.
TOO MUCH WATER IN
THE HEATING UNIT
• The solenoid valve of the automatic level de-
vice is faulty.
• The level probe is out of order (clogged by
lime-scale).
• Replace the solenoid valve of the automatic
level device.
• Replace the level probe.
WATER LEAKS FROM
THE MACHINE
• The tray is not draining.
• The drain pipe is broken, has detached, or the
water flow is obstructed.
• Water is leaking from the hydraulic circuit.
• Check the sewer drain.
• Check and restore the drain pipe connection to
the tray.
• Restore the hydraulic seal by replacing the
pipe, the gasket or the fitting as necessary.
WATER LEAKS FROM THE
DISPENSING GROUP
• The group gasket is worn. • Replace the group gasket.
THE GAUGE INDICATES A NON-
CONFORMING PRESSURE
• The pressure gauge is faulty.
• The pressure switch has been calibrated incor-
rectly.
• The motor pump has been calibrated incor-
rectly.
• Replace the pressure gauge.
• Adjust the pressure switch calibration.
• Adjust the motor pump calibration.
THE SAFETY VALVE
HAS CUT-IN
• The pressure transducer is broken.
• The electronic control unit is faulty.
• Check for correct operation of the pressure
transducer. Replace the safety valve with an
original spare part only.
• Check that the electronic system is working
properly.
STEAM DOES NOT COME
OUT OF THE NOZZLES
• The machine is switched o.
• The electrical heating element is faulty.
• The temperature probe is faulty.
• The nozzle sprayer is clogged.
• The safety thermostat is deactivated or faulty.
• Turn on the machine.
• Replace the electrical heating element.
• Replace the temperature probe.
• Clean the steam nozzle sprayer.
• Reactivate the thermostat or replace it.
WATER OR STEAM MIXED
WITH WATER COMES OUT
OF THE STEAM NOZZLES
• The level of the heating unit is too high due to
the level probe being incorrectly positioned in-
side the heating unit or the presence of lime-
stone.
• The heating unit filling solenoid valve is leak-
ing.
• Check the condition of the level probe: check
if it is positioned correctly and check for any
surface lime-scale.
• Clean and replace the filling solenoid valve.
NO COFFEE IS DISPENSING
• There is no water in the mains.
• The group solenoid valve is faulty.
• The pump is jammed.
• The group solenoid valve is clogged or dirty.
• The group filter is clogged.
• The volumetric dosing device is jammed.
• The inlet and outlet valves of the dosing device
are closed.
• Check that there is water in the mains.
• Replace the group solenoid valve.
• Replace the pump.
• Clean or replace the solenoid valve.
• Clean or replace the filter.
• Check/replace the dosing device.
• Open the valves.
THE COFFEE GROUNDS ARE
WET
• The group solenoid valve drain is clogged.
• The dispensing group is too cold.
• The coee has been ground too finely.
• There's not enough ground coee.
• Clean the group drain.
• Wait until the group has fully heated up.
• Adjust the coee grinder.
• Increase the amount of ground coee.