TECHNICIANS' manual
- English -
21 di 52
4. STORAGE
4.1 Overview
In the waiting period prior to installation, the machine must be
stored by the Manufacturer or an Authorised Distributor.
4.2 Storing the machine after operation
If the machine is not used after a certain period of time, store
it in the following conditions:
• Disconnect the machine from the water and power mains.
• Empty all the internal circuits of water.
Store the machine taking the following precautions:
• Store in a closed environment.
• Protect it from shocks and stresses.
• Avoid contact with corrosive substances.
The machine was designed and built to operate in environ-
ments with the following characteristics:
• Room temperature: +5°C - +35°C
• Max. relative humidity: 50% (at 40°C)
Any variation in these characteristics may decrease the average
life of some of the machine's components. Typical examples:
• Room temperature: premature degrading of the motors.
• Relative humidity: premature degrading of seals and elec-
tronics.
If the environmental features are significantly dif-
ferent than those listed, contact the MANUFAC-
TURER before they become a potential problem.
Before starting the machine up after it has been
placed in storage, the equipment must be fully in-
spected.
5. INSTALLATION
5.1 Safety precautions
Carefully read the instructions provided in chapter
"I. SAFETY PRECAUTIONS" on page 3.
If the technician has not performed all the installa-
tion operations and the machine is then used, this
may result in serious damage to the appliance and
people.
If any work is carried out on the machine electron-
ics when the machine is still live, any guarantee
will automatically be invalidated.
5.2 PPE features
When installing the machine, the following PPE is required:
The use of protective gloves is mandatory.
The use of eye protection is mandatory.
The use of safety shoes is mandatory.
5.3 Environmental conditions
5.3.1 Room temperature
The electrical and electronic equipment that has been installed
on the machine, has been designed and made to function
properly in environments where the temperature is between
+5 and +35°C.
5.3.2 Relative humidity
The electrical and electronic equipment that has been in-
stalled on the machine, has been designed and made to func-
tion properly in environments where the relative humidity
does not exceed 50% at a temperature of 40°C, or 90% at a
temperature of 20°C.
5.3.3 Altitude
The altitude of the installation site must not exceed 2000 m.