25
PARAMETERS TO MONITOR DURING REGULAR OPERATION
SR.NO PARAMETER UNIT VALUE REMARK
1
Oil pressure in main oil
passage
KPa 350~550
Rated speed
and power
2
Oil pressure in main oil
passage
KPa ≥100 Idle speed
3 Oil temperature in oil sump °C 85~115
4
Engine oil temperature at
normal operation
°C 75~105
5
Coolant outlet temperature at
normal operation
°C 70~95
It should not
exceed 95°C
6
Exhaust gas temperature
after gas turbine
°C <550
7
Inlet air temperature after air
cooler
°C 55 ± 5
Table 4.4
Before most of the failure, engine will develop early warning in the
from of abnormal sound, changes in parameter and performance or
engine appearance. Close monitoring of the engine will help to
detect the failure in the preliminary stage.
Few signs, to look out for are as below:
‒ Leakage of oil fuel, coolant, compressed air or exhaust gas
‒ Color change in exhaust gas
‒ Rise/drop of pressure and temperature
‒ Excessive vibration
‒ Sudden unusual noise
‒ Misring of engine
‒ Rise in oil/fuel consumption
‒ Power loss
Operation of diesel engine in winter
1. Fuel: Select and use the diesel of different brands according to the outdoor
temperature in winter.
2. Oil: Select the oil with different viscosities according to different seasons.
3. Coolant: Select and use different brands of anti-freeze additive and add
additive in different quantity into the cooling system according to the outdoor
temperature.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WEICHAI WP12 and is the answer not in the manual?

WEICHAI WP12 Specifications

General IconGeneral
Engine ModelWP12
Number of Cylinders6
Displacement11.596 L
Bore x Stroke126 mm x 155 mm
Compression Ratio17:1
Max Torque2100N.m
Weight1100 kg
Fuel SystemHigh Pressure Common Rail
Fuel Consumption≤195g/kWh

Related product manuals