26
4. Starting: In winter, use the auxiliary starter if required. It is allowed to run the
engine at higher speed and apply load after attaining the normal oil pressure
and water temperature.
Battery: Before beginning of winter season, check the electrolyte level, specic
gravity and cell voltage. If the diesel engine is not used for a long time and ambient
temperature is very low, then remove the battery and store it in a warm room.
Shutdown: When stopping the engine in cold weather, rst remove its load, then
the run the engine at idle speed for 3~4 minutes, stop the engine only after all
temperatures drop down. Do not drain off coolant with anti-freeze additive after the
engine is stopped. If the coolant is not added with the anti-freeze additive, then it is
necessary to open water drain valve and completely drain off all coolant. This will
prevent damages caused to the engine due to freezing

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WEICHAI WP12 and is the answer not in the manual?

WEICHAI WP12 Specifications

General IconGeneral
Engine ModelWP12
Number of Cylinders6
Displacement11.596 L
Bore x Stroke126 mm x 155 mm
Compression Ratio17:1
Max Torque2100N.m
Weight1100 kg
Fuel SystemHigh Pressure Common Rail
Fuel Consumption≤195g/kWh