EasyManua.ls Logo

Weidmüller MultiMark - Adjusting the transfer foil run

Weidmüller MultiMark
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setting up the printer
2903400000/00/09.202220
6.5 Adjusting the transfer foil run
Creases in the transfer foil run can lead to errors in the
print image. To avoid creasing, the transfer foil deection
(3) can be adjusted.
It’s best to perform this adjustment during print
operation.
Hexagon key
3
1
2
Image 6.6 Adjust the transfer foil run
Read the current setting on the scale (1) and note this
down.
Turn the screw (2) and observe the behaviour of the foil.
Turning in the + direction tensions the inner edge of the
transfer foil.
Turning in the direction tensions the outer edge of the
transfer foil.
Incorrect adjustment of the head locking system
can also cause creases in the foil run.

Related product manuals