8.1 SERIAL COMMANDS
COMMAND
Action performed
Capital letters
Lower
letter
M
Z
Manual zero function
M
T
Tare function
C
T
Clear the tare value
M
G
Toggle gross weight value on the display
M
N
Toggle net weight value on the display
S
C
Start continuous transmission
S
A
Start auto transmission
S
O
Enable command mode
%
Stop continuous transmission and enters the command mode
R
W
Send the current weight value show on the display
R
G
Send the current gross weight value
R
N
Send the current net weight value
R
T
Send the current tare weight
R
B
Send the current weight value show on the display (simple format)
R
H
Send the current gross weight value (simple format)
R
I
Send the current net weight value (simple format)
R
J
Send the current tare weight (simple format)
R
K
Send check weight status and the gross weight value
R
L
Send check weight status and the net weight value
Remarks:
Commands must be accompanied by terminating characters CR (0DH) and LF (0AH).
When a command is not accepted or is not correct, an error indication is sent in the
format: E: (Submitted character)
To use the command with address set RS1-12 and put the @ character in front of each
command as an example: