WEIGHTECH USA Weighing indicator WT3000-IR ABS Technical manual
Wt3000irabs v20151126
31
CFn-05
Função hold
hoLd 0
Hold function disabled
hoLd 0
hoLd 1
Peak detection.
To reset the function remove the weight applied and press any
key.
hoLd 2
Freezes the weight show on the display when stable.
To reset the function remove the weight applied and press any
key.
hoLd 3
Freezes the weight show on the display when stable.
The function will resets when the weight applied is less than
10d.
hoLd 4
Animal weighing mode.
At zero the indicator shows "---. ---" When a load is applied, the
indicator immediately starts the calculation of the applied load,
returning to indicate "---. ---" When the measured load is less
than 10d.
After activate the animal weighing is necessary to set the
parameters for calculating the weight.
Code
Description
Factory default
010%
Range of error in
measurement.
Range 1% to 100%
010%
8
Number of samples
used to calculate
the weight.
Range 1, 2, 4, 8, 16,
32 or 64 samples.
8
CFn-06
Auto zero
Z-tc 0
Disable auto zero
Z-tc 0
Z-tc 1
Enable auto zero

Related product manuals