3.2.1 Execute Fixed Calibration
This operation is used to measure the tool on a certain fixed position of the machine
tool to reconfirm tool offset. It helps to avoid tool length and the clamping position
vary during calibration due to tool damage or other causes.
It is mainly used for multi-tool mode and mainly used in the machine tool with tool
magazine.
Before executing fixed calibration, do the following:
1. Ensure parameter Calibration Type is set to 1.
2. Modify the value of parameter N75210 Fixed Presetter Position according to
the actual situation.
To execute fixed calibration, do the following:
1. To enter into Coor interface, in Auto / JOG / Handle / Step mode, press
→ 1.
2. Press F5. Fixed Calibrate (Measure Tool Length) dialog box pops up:
3. To select the target tool, input the target tool number in Define Tx input box.
4. To start fixed calibration, press F1.
Note: When the target tool number is different from that of current tool number, the system will
automatically change the tool before fixed tool calibration.