The system starts fixed calibration as follows, and saves the calibration result into
the tool length:
After fixed calibration, move the tool to the surface of the workpiece and do clearing.
See Do Clearing for details.
3.2.2 Execute First-time Calibration or Calibration after Tool Changed
This operation is used to compensate the calibration results to the workpiece offset.
Before executing first-time / calibration after tool changed, do the following:
1. Ensure parameter N75006 Calibration Type is set to 2.
2. To define Z-axis workpiece origin, manually move Z-axis to the workpiece
surface, and do clearing.
See Do Clearing for details.
To execute first / exchanged calibration, do the following:
1. To enter into Coor interface, in Auto / JOG / Handle / Step mode, press
→ 1.
2. Press F5. First-time Calibrate / Calibrate after Tool Changed dialog box
pops up: