118 3064298_201507
58. Technical parameters according to
EU regulation no. 813/2013
Type BWL-1S(B)-07/230V BWL-1S(B)-10/400V BWL-1S(B)-14/400V BWL-1SB-10/230V BWL-1SB-14/230V
Air-to-water heat pump [yes/no] yes yes yes yes yes yes yes yes yes yes
Water-to-water heat pump [yes/no] no no no no no no no no no no
Brine-to-water heat pump [yes/no] no no no no no no no no no no
Low-temperature heat pump [yes/no] no yes no yes no yes no yes no yes
Equipped with a supplementary
heater
[yes/no] yes/no yes/no yes/no yes/no yes/no yes/no yes/no yes/no yes/no yes/no
Heat pump combination heater [yes/no] no no no no no no no no no no
Values shall be declared for medium-temperature application (55°C)/low-temperature application (35°C)
for average climate conditions
Item Symbol Unit 55°C 35°C 55°C 35°C 55°C 35°C 55°C 35°C 55°C 35°C
Ratedheatoutput(*) P
rated
kW 6 7 11 10 13 12 10 10 11 12
Declared capacity for heating for
part load at indoor temperature
20°C and outdoor temperature
Tj= -7°C Pdh kW 6,0 5,9 8,3 8,5 9,2 11,0 8,0 9,0 7,9 9,8
Tj= +2°C Pdh kW 3,5 3,7 5,2 5,5 7,3 6,7 5,1 5,5 6,8 6,7
Tj= +7°C Pdh kW 2,9 2,8 4,5 5,0 4,7 5,1 4,6 4,8 4,7 4,9
Tj= +12°C Pdh kW 3,1 3,4 5,1 5,9 4,9 5,1 5,6 5,8 5,5 5,2
Tj= bivalent temperature Pdh kW 4,7 5,9 8,0 9,3 8,9 10,8 7,8 7,9 8,3 8,9
Tj= operation limit temperature Pdh kW 5,5 6,6 8,2 9,3 9,4 10,8 6,8 9,1 6,8 8,7
For air-to-water heat pumps Tj =
-15°C (if TOL < -20°C)
Pdh kW - - - - - - - - - -
Bivalent temperature T
biv
°C -3 -7 -3 -8 -3 -8 -5 -5 -3 -4
Seasonal space heating energy
efciency
n
s
% 133 180 130 195 131 178 111 150 111 150
Declaredcoefcientof
performance or primary energy
ratio for part load at indoor
temperature 20°C and outdoor
temperature
Tj= -7°C COPd - 2,11 2,96 2,05 2,97 2,03 2,86 1,64 2,52 1,61 2,23
Tj= +2°C COPd - 3,41 4,33 3,22 5,00 3,25 4,04 2,89 3,63 3,01 3,93
Tj= +7°C COPd - 4,12 5,95 4,30 6,21 4,77 6,68 4,10 5,34 4,29 5,51
Tj= +12°C COPd - 5,31 7,21 5,30 7,36 5,20 8,58 5,23 7,32 4,95 5,27
Tj= bivalent temperature COPd - 2,60 2,96 2,51 3,08 2,51 2,86 1,85 2,84 2,01 2,82
Tj= operation limit temperature COPd - 1,85 2,66 1,86 2,81 1,86 2,86 1,38 2,10 1,38 2,04
For air-to-water heat pumps Tj =
-15°C (if TOL < -20°C)
COPd - - - - - - - - - - -
For air-to-water heat pumps:
Operation limit temperature
TOL °C -10 -10 -10 -10 -10 -10 -10 -10 -10 -10
Heating water operating limit
temperature
WTOL °C 55 55 55 55 55 55 55 55 55 55
Power consumption in modes
other than active mode: Off
mode
P
OFF
kW 0,007 0,007 0,026 0,026 0,026 0,026 0,026 0,026 0,026 0,026
Power consumption in modes
other than active mode:
Thermostat-off mode
P
TO
kW 0,011 0,011 0,026 0,026 0,026 0,026 0,026 0,026 0,026 0,026
Power consumption in modes
other than active mode: Standby
mode
P
SB
kW 0,010 0,010 0,026 0,026 0,026 0,026 0,026 0,026 0,026 0,026
Power consumption in modes
other than active mode:
Crankcase heater mode
P
CK
kW 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000 0,000
Supplementary heater: Rated
heat output
P
sup
kW 0,9 / 0,0 0,1 / 0,0 2,6 / 0,0 0,8 / 0,0 3,5 / 0,0 2,8 / 0,0 2,84 / 0,0 0,7 / 0,0 4,61 / 0,0 2,9 / 0,0
Type of energy input - - electrical electrical electrical electrical electrical
Capacity control xed/variable variable variable variable variable variable
Sound power level, indoors L
WA
dB 42 42 42 42 44 44 42 42 44 44
Sound power level, outdoors L
WA
dB 61 61 60 60 61 61 61 61 61 61
For air-to-water heat pumps:
Ratedairowrate,outdoors
- m3/h 2600 2600 3500 3500 4200 4200 3800 3800 3800 3800
For water-/brine-to-water heat
pumps: Rated brine or water
owrate
- m3/h - - - - - - - - - -
Contact details Wolf GmbH, Industriestraße 1, D-84048 Mainburg
(*)Forheatpumpspaceheatersandheatpumpcombinationheaters,theratedheatoutputP
rated
is equal to the design load for heating P
designh
, and the rated heat output of a supplementary
heater P
sup
is equal to the supplementary capacity for heating sup(Tj).