6 3064298_201507
The heat pump system must be sited, installed, set up and commissioned by
aqualiedcontractor,incompliancewiththeapplicablestatutoryregulations,
ordinances and directives and the installation instructions.
The tilting angle of the heat pump during transport must be no greater than 45°.
Under no circumstances must the components and pipework of the refrigerant circuit,
the heating circuit or the heat source side be used to transport the appliance.
The heat pump must only be operated with outdoor air as the heat source. The air-
conducting sides must not be constricted or obstructed.
For safety reasons, the power supply to the heat pump and the control system must
not be interrupted, even outside the heating period.
Reason: No monitoring of HC pressure, no frost protection, no anti-seizing pump
protection.
Theappliancemayonlybeopenedbyaqualiedcontractor.
Before opening the appliance, all electrical circuits must be isolated from the power
supply. Take precautions to prevent the fan from starting up unintentionally. The
system must be isolated from the power supply across all poles and safeguarded
against reconnection.
Workontherefrigerantcircuitmustonlybecarriedoutbyaqualiedcontractor.
DonotuseTeonsealantintheheatingcircuit,asthismayresultinleaks.
Never treat appliance surfaces with scouring agents or cleaning agents containing
acid or chlorine.
When siting the heat pump, position and install it securely, to prevent it slipping or
sliding during operation.
The outdoor unit may only be installed outdoors.
Only replace faulty components with original Wolf spare parts.
Observethespeciedelectricalfuseratings
(seeSpecication).
AnydamageorlossresultingfromtechnicalmodicationstoWolfcontrolsystemsis
excluded from our warranty.
Risk of water damage and faulty operation through freezing.
The heat pump is automatically protected from frost when it is switched on.
For installation in Austria:
Observe the ÖVE regulations and requirements and those of your local power supply
utility.
Thelocalpowersupplyutilitymustbenotiedwhenaheatpumpisinstalled.
The installation and operating instructions are valid as of software version
1.30 for printed circuit board HCM-3 and as of software version 1.40 for the AM
display module.
Please note
Please note
The following regulations and directives must be observed when carrying out
installation, commissioning, maintenance and repair work:
2. General information