Contractor
parameter
Meaning Setting range Factory setting Individual setting
Compressor
WP080 BWL-1S(B)-07 dual mode point,
compressor
-20.0 °C ... 45.0 °C -15.0 °C
WP080
BWL-1S(B)-10/14 dual mode point, compressor
-20.0 °C ... 45.0 °C -20.0 °C
Electric heater, add. ht. gen.
WP090 Enable electric heating for heating mode Off, On ON
WP091 Dual mode point, electric heating -20.0 °C ... 45.0 °C -5.0 °C
WP092 Power-OFF for electric heating Off, On On
WP093 Temporary deactivation of WP091 0 to 40 days 0 days
WP094 Type of electric heating None, 2 kW, 3 kW,
4 kW, 6 kW, 9 kW
6 kW
WP101 Dual mode point, add. ht. gen. -20.0 °C ... 45.0 °C 0.0 °C
Other
WP121 Max. compressor starts per hour 3 ... 10 / h 3 / h
31. Contractor level
*Contractorparametersareautomaticallypre-setdependingontheselectedsystemconguration.