EE--SSeerriieess WWaallll OOvveenn
EE--SSeerriieess WWaallll OOvveenn
Troubleshooting Guide
5-11
Figure 5-10. Error Codes and Displayed Messages
System Failures
ERROR CODE CHART (cont.)
Priority Displayed Phrase Service Instruction
3 UIM EE checksum error
Replace UIM Module
1 UIM configuration data CRC error
1 UIM fuse error
3 UIM ambient thermistor open error
3 UIM ambient thermistor shorted error
1 LCD module error
2 Communications error detected by the UIM Check com harness, replace Relay Module
2 Communications error detected by the RM Check com harness, replace UIM Module
2 Overtemp error - door unlocked Check door motor assy & wiring, replace Relay Module
2 Overtemp error - door locked Replace Relay Module
2
RM Ambient overtemp error
Check air flow, verify cooling fan operational, replace relay
module
2
UIM Ambient overtemp error
Check air flow, verify cooling fan operational, replace UIM.
3
Self-clean rate-of rise error
Check ovenfor leaks, insulation problems. Run diagnostics,
look for open ouptuts or loads