Priority Displayed Phrase Service Instruction
2 RTD Open
(Upper/Lower) RTD failure (device or
wiring)
2 RTD Shorted
2 Temp Probe Short
(Upper/Lower) Meat Probe failure
(device or wiring)
3 No Inner Bake element detect
Check specified element & wiring
3 No Outer Bake element detect
3 No Broil element detect
3 No Lt Conv element detect
3 No Rt Conv element detect
3 No MDL detect Check specified MDL & wiring
3 No Left Convect Fan detect
Check specified fan & wiring
3 No Rt Convect Fan detect
3 No Cooling Fan detect
3 No Oven Light detect
Check specified oven light trans-
former & wiring
2 Lock inputs invalid
Check door motor assy & wiring
2
Lock/Door inputs invalid for
Clean
2 MDL run timeout
2 TCO detect as open
Check air flow, verify cooling fan
operational
2 Brownout error
Check home wiring, voltages, replace
Relay Module
2 Inner Bake relay shorted
Check connections, replace Relay
Module of the oven indicated
3 RM Ambient Thermistor shorted
Check connections, replace Relay
Module of the oven indicated
3 RM Line Voltage A/D error
2 MDL circuitry error
2 RM FMEA circuitry error
E-SERIES Error Code Chart