Verification of power voltage
PRINCESS – Edition: 17.02.2005
51
FIELD SERVICE MANUAL
12.3 Verification of power voltage
The voltage settings are marked on
the cover plate of the mains transfor-
mer. Machines for USA are set to
117V. They have a special transfor-
mer according to UL standard which
is not adjustable. Jukeboxes “UNI-
Pack” are shipped in 230V setting.
This is marked on the machine label
inside of the door. If the voltage set-
ting is not clear the transformer cover
plate has to be removed. The mains
fuse (T3.15A) is located on the left
bottom side inbetween the three ter-
minals for the bill acceptor, the exter-
nal mains switch and the fluorescent
lamps.
Loosen the four screws to remove the
cover plate (small arrows).
ATTENTION! Always remove power plug before opening transformer cover plate. Never
attempt any intervention to these parts unless qualified!
The position of the two plug connectors on the transformer terminals 1 to 9 (primary side) indicates
the current voltage setting. The following combinations are possible:
240V = 1 - 9
230V = 1 - 8
220V = 2 - 9
210V = 2 - 8
117V = 1 - 6
100V = 2 - 6
Notice that these settings cannot be
made on machines produced accor-
ding to UL standard.
NOTE: Never connect the fluorescent
supply to other contact.
If you intend to change the power vol-
tage for a higher voltage (e.g. from
117V to 230V) it is better to use a
subtransformer for the fluorescent
lamps or change the ballast according
to the used voltage (e.g. for 230V).
Netzsicherung
Mains Fuse
210-240V - T 4A
100-117V - F 6A
Leuchtstofflampen
Fluorescent Lamps
230V / 117V
Verstärker
Amplifier
Externer Hauptschalter
External Mains switch
Schein-
annehmer
Bill-
acceptor
Achtung
Vor A nahme er appe en Netzstecker
ziehen
arning
Shock hazar o not open
ur Beachtung Nur Sicherungen mit
gleicher ße un gleichem ert
erwen en, um Schä en zu ermei en
aution To re uce the risk of fire
replace onl with same t p an rating fuses
Netzspannung
50/60 Hz
Mains Voltage
50/60 cps
240
230
220
210
117
100
Netzsicherung/
Mains Fuse
210-240V - T3,15A
100-117V - F6A
Deutsche Wurlitzer GmbH