20 I-Class
3.2 Media Sensor Adjustment
The Media Sensor needs to be positioned so that the printer can detect the
presence of media and the top-of-form (except for continuous stock, where the
TOF is set through programming; see Label Length, Section 4.1.2). To adjust:
Œ With media loaded, as described in Section 3.1.1 or 3.1.2, grasp the Slide
Tab and move the Sensor Eye Mark into position over media according to
the table below.
If loading media, return to the media loading instructions.
Media Sensor Selection and Adjustment
Media Type Sensor Eye Mark Position Sensing Required
*
Die-cut Near the middle of the label Gap
Notched Centered over the notch Gap
Reflective Centered over the black mark Reflective
Continuous Near the middle of the media Continuous
*
See Section 4.1.2 for Sensor Type selection.
þ Note: Changes to the start of print position can be made using the Print
Control/Row Adjust or Row Offset (see Section 4.1.3).