28 www.xilinx.com SP605 Hardware User Guide
UG526 (v1.9) February 14, 2019
Chapter 1: SP605 Evaluation Board
SMA Connectors (Differential)
A high-precision clock signal can be provided to the FPGA using differential clock signals
through the onboard 50Ω SMA connectors J38 (N) and J41 (P).
8. Multi-Gigabit Transceivers (GTP MGTs)
The SP605 provides access to 4 MGTs.
One (1) MGT is wired to the PCIe x1 Endpoint (P4) edge connector fingers
One (1) MGT is wired to the FMC LPC connector (J2)
One (1) MGT is wired to MGT SMA connectors (J36, J37)
One (1) MGT is wired to the SFP Module connector (P2)
The SP605 includes a set of six SMA connectors for the GTP (MGT) RX/TX Port and GTP
(MGT) Clock as described in Figure 1-10 and Table 1-10.
Table 1-9: SP605 Clock Source Connections
Source U1 FPGA Pin Schematic Net Name
Pin
Number
Pin Name
U6 200MHZ OSC
K22 SYSCLK_N 5 OUT_B
K21 SYSCLK_P 4 OUT
X2 27MHZ OSC AB13 USER_CLOCK 5 OUT
USER_SMA_CLOCK M19 USER_SMA_CLOCK_N J38.1
SMA Connectors M20 USER_SMA_CLOCK_P J41.1