P9-00
Communication
protocol
Runtime
read
only
1
0-2
EtherCAT
P9-12
Slave station No.
RW
-
0-65535
After modification, it is valid
when power on again.
Note: When using the CiA402 protocol for control, other parameters of the frequency converter can be factory
parameters. If the master station supports automatic reading of the slave station number (e.g. Xinje bus type PLC),
P9-12 does not need to be set.
10.1.3.2 Add XML file
Before opening the PLC software, you need to add the XML file. (when installing the XDPPro software, the XML
file of frequency conversion has been included.) If you need to update the XML file, please go to the official
website service and support download center to download it by yourself.
Right click XDPPro software, open the location of the file, find the directoryplugins\ ethercat\vendorxml, and
add the XML file here.
10.1.3.3 New project(take XDH-60T4 as an example)
10.1.3.4 Master connection configuration
1.Computer configuration
After the network cable is plugged in, open "control panel" "network and Internet" "network connection".
Find the Ethernet that has been successfully connected. Right click the Ethernet and click properties. The Ethernet
properties interface pops up. Then follow the steps below: