EasyManua.ls Logo

XLT Ovens X3F3-1832 Series - Page 37

XLT Ovens X3F3-1832 Series
118 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Support US: 888-443-2751 Technical Support INTL: 316-943-2751
37
OVEN OPERATOR CONTROLS
Remote Hood Switch
Factory default is NO. If there is a Remote Hood Switch installed, then press ENTER
and NO flashes. Use Up/Down arrows to change to YES. Press ENTER to accept and
advance.
Fuel Type
Gas or Electric. Factory default is Gas. To Change press ENTER. Use Up/Down ar-
rows and ENTER to accept and advance.
Temp Offset Adjust
Factory default is zero. Allows the field tech to make adjustments up to +/- 20 degrees
in temperature.
High Temp
Can be reduced in only 10 degree increments from factory default of 590 degrees Fahr-
enheit. No less than 500 degrees Fahrenheit. To change press ENTER and use Up/
Down arrows to change and press ENTER to accept and advance.
Low Temp
The Oven can be reduced to 300 degrees Fahrenheit the factory default is 350 degrees
Fahrenheit. If the field tech reduced temp to 300 degrees the control will allow it and
display “Valve Change Reqd” To change press ENTER and use Up/Down arrows to
change and press ENTER to accept and advance.
Main Fan
Only for units with On/Off main fan. VFD units are 3 phase, no monitoring by this
control. This screen display shows Amp load on fan motor.
Belt Direction
If the belt direction needs changed from either Left to Right or Right to Left, then
press ENTER and use Up/Down arrows to change the setting. The wire belt is non-
directional and doesn’t physically need changed. If the conveyor is a split belt, then use
the TIME button to toggle between belts. Press ENTER to accept and advance.
Main Fan Off Delay
To change press ENTER to highlight AUTO. Use Up/Down arrows to change to
(TIMED 30:00) and press ENTER to accept and exit.
Beeper Button Test
Press ENTER to enter setting. A beep with each press of a button. Press ENTER to
exit.