FT-920 Operating Manual
81
U-58 ( RLSBCAR )
Function: Set the RX Carrier Point for LSB
Available Values: - 0.300 ~ 0.500 kHz
Dafault: 0.000
Changing this value is analogous to rotating the IF
SHIFT control, allowing you to preset the frequency
response of the receiver during LSB operation. The
effect of the adjustment can be heard if you turn the
volume up while rotating the VFO-B Tuning Dial to
adjust the setting.
U-59 ( TLSBCAR )
Function: Set the TX Carrier Point for LSB
Available Values: - 0.300 ~ 0.500 kHz
Dafault: 0.000
This is the same function as that of Menu Item U-58,
as applied to your voice response on LSB (TX). The
effect may be difficult to discern, however, depend-
ing on the settings of the TX Equalizer via Menu Item
U-51.
U-60 ( PROCLSB )
Function: Set the TX Carrier Point for LSB when the
Speech Processor is on
Available Values: - 0.300 ~ 0.500 kHz
Dafault: 0.000
This is the same function as that of Menu Item U-59,
but is applied to your voice response on LSB (TX)
when the Speech Processor is on. Therefore, it is
possible to set two different response characteristics
for your voice, one for “Processor-On” and one for
“Processor Off.”
U-61 ( RUSBCAR )
Function: Set the RX Carrier Point for USB
Available Values: - 0.300 ~ 0.500 kHz
Dafault: 0.000
Changing this value is analogous to rotating the IF
SHIFT control, allowing you to preset the frequency
response of the receiver during USB operation. The
effect of the adjustment can be heard if you turn the
volume up while rotating the VFO-B Tuning Dial to
adjust the setting.
U-62 ( TUSBCAR )
Function: Set the TX Carrier Point for USB
Available Values: - 0.300 ~ 0.500 kHz
Dafault: 0.000
This is the same function as that of Menu Item U-58,
as applied to your voice response on USB (TX). The
effect may be difficult to discern, however, depend-
ing on the settings of the TX Equalizer via Menu Item
U-51.
U-63 ( PROCUSB )
Function: Set the TX Carrier Point for USB when the
Speech Processor is on
Available Values:
- 0.300 ~ 0.500 kHz
Dafault: 0.000
This is the same function as that of Menu Item U-59,
but is applied to your voice response on USB (TX)
when the Speech Processor is on. Therefore, it is
possible to set two different response characteristics
for your voice, one for “Processor-On” and one for
“Processor Off.”
U-64 ( VOX-DLY )
Function: Set the “hang time” for the VOX circuitry
Available Values: 0 ~15
Default: 5 (Corresponding to 1 second)
The above scale of 1 ~ 15 is in 0.2 second incre-
ments, allowing precise setting of the desired VOX
recovery time.
U-65 ( VX-GAIN )
Function: Set the gain of the VOX circuitry’s input
audio detector
Available Values: 0 ~15
Default:15
The adjustment values are an arbitrary scale. Set the
VOX Gain to the level which quickly activates the
transmitter, yet does not pick up extraneous noises
in your operating room.