Troubleshooting
PROBLEM POSSIBLE CAUSE PROCEDURE OR ACTION
Lift truck will not move. Dead battery. Recharge or replace battery.
Failed (Open) fuse. Replace Failed (Open) fuse.
Brake is applied. Test the brake to ensure wiring to
brake is good.
Drive motor not operating. Repair or replace drive motor.
Sequencing fault. Return handle to rest and recycle.
Mast will not raise the forks. Dead battery. Recharge or replace battery.
Failed (Open) fuse. Replace Failed (Open) fuse.
Lift pump motor wiring loose or dis-
connected.
Reconnect or tighten loose wiring
connections.
Lift pump motor not operating. Repair or replace lift pump motor.
Operator controls do not work. Dead battery. Recharge or replace battery.
Failed (Open) fuse. Replace Failed (Open) fuse.
Control handle wiring loose or dis-
connected.
Check wiring and tighten or con-
nect as needed.
An individual switch is damaged. Check switch and replace if inoper-
ative.
Troubleshooting 2200 YRM 1007
54