12. AD DATA CHECK / FAN TEST
This menu is used to display the A/D conversion value
of the main CPU which detects panel keys of the main
unit and protection functions in % using the sub-menu.
During signal processing, the condition before
execution is maintained.
When K0/K1 menu is selected, keys become non-
operable due to detection of the values of all keys.
However, it is possible to advance to the next sub-
menu by turning the VOLUME of the main unit. When
using this function, note that turning the VOLUME more
than 1 click would cause the volume value to change.
* The figures in the diagram are given as reference
only.
12.ADDATACHECK/FANTEST
本体パネルキー、プロテクションなどを検出しているメ
インCPUのA/D変換の値を、サブメニューで%表示しま
す。信号処理は実行前の状態を維持します。
K0/K1のメニューにすると、全キーの値を検出するため
キー操作はできなくなりますが、本体のVOLUMEを回
すことにより、次のサブメニューに進めることができま
す。このとき1クリック以上回すと、ボリューム値が変
化するので注意してください。
※図中の数値は参考例です。
TH1/TH2 (temperature detection)
500% display of the voltage based on the temperature
detected value.
Reference voltage: 5V=500%
(Normal value: 39 to 182) U, C, T, K, A, B, G models
(Normal value: 39 to 176) R, L, J models
TH1: Detects the temperatur of the front heat sink.
TH2: Detects the temperatur of the rear heat sink.
TH1/TH2(温度検出)
温度検出値で電圧の500%表示、基準電圧は5V(正常値:
3〜176)
TH1: フロントヒートシンクの温度を検出しています。
TH2: リアヒートシンクの温度を検出しています。
REC-OUT (Select position) REC-OUT(選択位置表示)
PS1/PS2 (Power supply voltage protection detection)
Power supply voltage protection value (Normal value:
PS1: 29 to 39, PS2: 24 to 36)
PS1: Detects ±B1, ±B2, ±B4, ±B5, ±12V, +5D1, +5D2 and
+2.5D.
PS2: Detects +9V, ±5V and +3.3V.
* If PS is out of the normal value range, the protection
function works to turn off the power.
(Reference voltage: 5V=100%)
PS1/PS2(電源電圧プロテクションの検出)
プロテクションの値(正常値PS1:29〜39、PS2:24〜
36)
PS1: ±B1、±B2、±B4、±B5、±12V、+5D1、
+5D2、+2.5Dを検出しています。
PS2: +9V、±5V、+3.3Vを検出しています。
PSは正常値を外れるとプロテクションが働き、電源オ
フされます。
(基準電圧:5V=100%)
DC/FAN OUT (protection detection/fan drive level)
DC: DC detect protection value (Normal value: 1 to 13)
Fan: Current fan drive level on the left and the past fan
drive history on the right.
* If DC is out of the normal value range, the protection
function works to turn off the power.
(Reference voltage: 5V=100%)
DC/FUNOUT(プロテクションの検出/ファン駆動レベル)
DC: DC検出プロテクションの値(正常値1〜13)
Fan:
左側は現在のファン駆動レベル、右側は過去のファ
ン駆動履歴
DCは正常値を外れるとプロテクションが働き、電源オ
フされます。
(基準電圧:5V=100%)
Display H M L
fan drive level HIGH MID LOW
[Table 1]
REC OUT Select
DVR/VCR2
VCR1
CBL/SAT
DTV
DVD
SOURCE (
/REMOTE
)
MD/TAPE
CD-R
TUNER
CD
Value
46
168
138
15
76
200
184
61
0