68
MOX6/MOX8
4. Other Inspections
Turn on the [STANDBY/ON] switch to start up on the normal mode.
Pop-Noise (PHONES)
Connect the oscilloscope to the [PHONES] terminal (L and R).
Turn on and off the [STANDBY/ON] switch sequentially.
Confi rm each output level is as follows at that time.
PHONES L: 500mVp-p or less
PHONES R: 500mVp-p or less
Pop-Noise (OUTPUT)
Connect the oscilloscope to the OUTPUT terminals ([L/MONO] and [R]).
Insert the jacks to both the [L/MONO] and [R] terminals at the same time.
Turn on and off the [STANDBY/ON] switch sequentially.
Confi rm each output level is as follows at that time.
OUTPUT L: 500mVp-p or less
OUTPUT R: 500mVp-p or less
Noise Level (PHONES)
Connect the level meter to the [PHONES] terminal (L and R).
Make sure the A/D INPUT [ON/OFF] switch is turned off (The LED is off).
Confi rm each output level is as follows at that time.
PHONES L: -85.0dBu or less
PHONES R: -85.0dBu or less
Noise Level (OUTPUT)
Connect the level meter to the OUTPUT terminals ([L/MONO] and [R]).
Insert the jacks to both the [L/MONO] and [R] terminals at the same time.
Make sure the A/D INPUT [ON/OFF] switch is turned off (The LED is off).
Confi rm each output level is as follows at that time.
OUTPUT L: -85.0dBu or less
OUTPUT R: -85.0dBu or less
5. Initial Settings
Set each controller to the factory default settings as follows.
[STANDBY/ON]: OFF
[MASTER VOLUME]: Min.
[DAW LEVEL]: Min.
A/D INPUT [GAIN]: Min.
MODULATION WHEEL: Min.