18 If the battery is discharged
133
WARNING
Do not connect the connection cables to the terminals in reverse polarity. For example,
never connect the negative terminal on one machine to the positive terminal on the other
machine. A polarity reversal may damage the alternator.
When the battery is charging, remove all the plugs to release the gases generated.
If the battery overheats (the electrolyte temperature exceeds 45°C), stop the operation.
Stop the charging operation as soon as the battery is charged. If you continue, the follow-
ing faults may occur :
battery overload
reduction in the battery electrolyte
battery failure
The battery must only be handled once the cables have been disconnected (except for
checking the level of electrolyte and the specified electrolyte density measurement).
Connecting
To connect, start with the positive terminal. (+)
18.5 Charging the battery
Disconnecting
To disconnect, start with the negative terminal. (-)
Charging the battery
WARNING
Remove the cables from the positive and negative terminals of the battery before setting
the battery to charge. Otherwise, abnormal voltage may be applied to the alternator and
may damage it.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yanmar ViO80-1A and is the answer not in the manual?

Yanmar ViO80-1A Specifications

General IconGeneral
BrandYanmar
ModelViO80-1A
CategoryExcavators
LanguageEnglish

Related product manuals