Installation 1-4
Installation and Wiring
Verify Drive Operation
1. Connect power to the drive and verify that the drive functions properly. This includes running the drive from the operator keypad. Refer
to the V7 Drive Technical Manual, TM.V7.01, for information on connecting and operating the drive.
2. Remove power from the drive and wait for the charge lamp to be completely extinguished. Wait at least five additional minutes for the
drive to be completely discharged. Measure the DC bus voltage and verify that it is at a safe level.
Prepare the V7 Drive
1. Remove the operator keypad and V7 Drive cover.
2. Remove the terminal cover
3. Remove the CN2 cover from the V7 Drive housing. Carefully snip the 3 tabs connecting the CN2 cover to the V7 housing and remove
the cover.
4. Attach the Mounting Bracket. Align the mounting bracket as shown in the figure to the right. Secure the mounting bracket to the V7
Drive housing using the M3 x 8 screw provided.
Fig 1.2 – Prepare the V7 Drive
Dangerous voltages in excess of 400VDC (230V drives) or 800VDC
(460V drives) are present at the DC bus terminals of the drive.
WAR NIN G!