EasyManua.ls Logo

YASKAWA CIPR-GA50C series - Page 25

YASKAWA CIPR-GA50C series
310 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 English
YASKAWA TOMPC71061753A YASKAWA AC Drive GA500 Installation and Operation Instruction 25
No.
(Hex.)
Name Description
d2-02 Frequency Reference
Lower Limit
Sets minimum limit for all frequency references. The maximum output
frequency is 100%.
E1-01 Input AC Supply
Voltage
Sets the drive input voltage.
E1-04 Maximum Output
Frequency
Sets the maximum output frequency for the V/f pattern.
E1-05 Maximum Output
Voltage
Sets the maximum output voltage for the V/f pattern.
E1-06 Base Frequency Sets the base frequency for the V/f pattern.
E1-09 Minimum Output
Frequency
Sets the minimum output frequency for the V/f pattern.
E2-01 Motor Rated Current Sets the motor rated current in amps.
E2-11 Motor Rated Power Sets the motor rated output in the units from o1-58 [Motor Power Unit
Selection].
H1-01 - H1-
07
Terminal S1 to S7
Function Selection
Sets functions for MFDI terminals S1 to S7.
H2-01 Term MA/MB-MC
Function Selection
Sets a function for MFDO terminal MA-MC or MB-MC.
H2-02 Term P1-C1 Function
Selection
Sets a function for MFDO terminal P1-C1.
H2-03 Term P2-C2 Function
Selection
Sets a function for MFDO terminal P2-C2.
H3-01 Terminal A1 Signal
Level Select
Sets the input signal level for MFAI terminal A1.
0: 0 to 10V (Lower Limit at 0), 1: 0 V to 10 V (Without Lower Limit)
H3-02 Terminal A1 Function
Selection
Sets a function for MFAI terminal A1.
H3-03
RUN
Terminal A1 Gain
Setting
Sets the gain of the analog signal input to MFAI terminal A1.
H3-04
RUN
Terminal A1 Bias
Setting
Sets the bias of the analog signal input to MFAI terminal A1.
H3-09 Terminal A2 Signal
Level Select
Sets the input signal level for MFAI terminal A2.
0: 0-10V (LowLim=0), 1: 0 V to 10 V (Without Lower Limit), 2: 4 to 20 mA,
3: 0 to 20 mA
H3-10 Terminal A2 Function
Selection
Sets a function for MFAI terminal A2.
H3-11
RUN
Terminal A2 Gain
Setting
Sets the gain of the analog signal input to MFAI terminal A2.
H3-12
RUN
Terminal A2 Bias
Setting
Sets the bias of the analog signal input to MFAI terminal A2.
H3-13 Analog Input
FilterTime Constant
Sets the time constant to apply a primary delay filter to the MFAI terminal.