6 Troubleshooting
6.4 Redisplaying the Touch Calibration Display
6-8
165559-1CD
HW1481993
DX200 Standard Setup
6.4 Redisplaying the Touch Calibration Display
The touch calibration display can be redisplayed with the following
procedures:
(1) While pressing [HIGH SPEED] and [SLOW] simultaneously, turn
ON the DX200 main power supply.
(2) A crosshair cursor at the center of the display moves in the follow-
ing order: Center Upper left Lower left Lower right
Upper right.
Press the center of the cursor for approx. 2 seconds at each point.
If the touch calibration is failed, the cross cursor returns to the center
of the display. In this case, retry the calibration.
When the touch calibration is successfully completed, the following
display appears.
(3) The following display appears by pressing [ENTER] button on the
programming pendant or by touching the display.