6     Troubleshooting
6.4  Redisplaying the Touch Calibration Display
6-8
165559-1CD
HW1481993
DX200 Standard Setup
6.4 Redisplaying the Touch Calibration Display
The touch calibration display can be redisplayed with the following 
procedures:
(1) While pressing [HIGH SPEED] and [SLOW] simultaneously, turn 
ON the DX200 main power supply.
(2) A crosshair cursor at the center of the display moves in the follow-
ing order: Center → Upper left → Lower left → Lower right → 
Upper right.
– Press the center of the cursor for approx. 2 seconds at each point.
– If the touch calibration is failed, the cross cursor returns to the center 
of the display. In this case, retry the calibration.
– When the touch calibration is successfully completed, the following 
display appears.
(3) The following display appears by pressing [ENTER] button on the 
programming pendant or by touching the display.