User Constant Tables
5-55
U1-81
Error status 2 Inverter error status 2.
Low/High register is changed by the
digital operator [DATA/ENTER] key.
Lower register(L) status
High register(H) status
− [Bit] A A 90H
Error Sts 2
U1-82
Error status 3 Inverter error status 3.
Low/High register is changed by the
digital operator [DATA/ENTER] key.
Lower register(L) status
High register(H) status
− [Bit] A A 91H
Error Sts 3
Constant
Number
Name
Description 100% Value
Min.
Unit
Control
Methods
MEMOBUS
Register
Display
Open-
loop
Vector
Flux
Vector
1: External fault S3 (EF3)
1: External fault S4 (EF4)
1: External fault S5 (EF5)
1: External fault S6 (EF6)
1: External fault S7 (EF7)
1: External fault S8 (EF8)
1: External fault S9 (EF9)
1: External fault S10 (EF10)
00000000
1: External fault S11 (EF11)
1: External fault S12 (EF12)
1: External fault S13 (EF13)
1: External fault S14 (EF14)
1: External fault S15 (EF15)
1: External fault S16 (EF16)
Not Used
Not Used
00000000
1: Control fault (CF)
Not Used
1: External fault input from
PLC (EF0)
Not Used
Not Used
Not Used
Not Used
1: Undertorque 1 (UL3)
00000000
1: Undertorque 2 (UL4)
1: Input over voltage (IOV)
1: Input under voltage (IUV)
1: Cell fuse blown (FUB)
1: CCB control power
supply error (UVB)
1: Cell data communication
error (CDE)
1: Output over voltage (OOV)
1: Hardware error (CPFxx)
00000000