1-12
Transportation and Installation
Transporting the FSDrive-MV1S Series Inverter
To lift the small/middle capacity (3 kV class 200 to 2300 kVA, 6 kV class 400 to 2300 kVA) Inverter, use
the fixtures indicated on the panels.
To lift the large capacity (3 kV class 3000 kVA, 6 kV class 3000 to 6000 kVA) Inverter, use the lifting tool
provided as an accessory to lift only the Transformer Panel.
Never climb on the panel top.
The exhaust louver on the panel top can be easily damaged by external force.
Side-by-Side Installation
For Inverters of capacity 2300 kVA or more of both 3 kV class and 6 kV class, the panels are designed to be
installed side-by-side.
For these models, eight (8) holes are provided each on the Transformer Panel frame and Power Cell Panel
frame as shown in Fig. 1.4.
Use M10×30L bolts, washers, and S washers to joint the panels.
Fig 1.4 Mounting Holes for Side-by-Side Installation (Example of 3 kV 2300 kVA Inverter)
Movement of the Inverter with a crane must be performed only by a qualified crane oper-
ator.
Failure to observe this precaution may result in injury or in dropping the Inverter.
CAUTION
Transformer Panel Cell Panel