Installing an Inverter on a Floor
The table below shows the mounting holes and dimensions when installing an Inverter on a floor.
Use mounting screws of diameter M12 to affix the Inverter.
Attach and fasten M12 screws at all the mounting holes to secure the Inverter in any installation conditions,
whether there is vibration or not.
Panel Bottom Dimensional Drawing 1
Table 1.4 FSDrive-MV1S Installation Dimensions
Voltage
Class
Frequency
[Hz]
FSDrive-MV1S Model
CIMR-MV1S
Panel
Bottom
Dimensional
Drawing
Dimensions [mm]
Mounting
Hole
N-φ
w1 w2 w3 d
3 kV 50/60
132 1 980 1080 - 935 6-φ17
200 1 980 1080 - 935 6-φ17
315 1 1080 1080 - 935 6-φ17
450 1 1080 1080 - 935 6-φ17
630 1 1080 1080 - 935 6-φ17
900 2 1780 1180 - 1135 6-φ17
13C 2 1780 1180 - 1135 6-φ17
18C 2 1760 1360 - 1135 8-φ17
25C 4 1380 2360 - 1335 10-φ17
6 kV 50/60
250 2 1780 1380 - 935 6-φ17
400 2 1780 1380 - 935 6-φ17
630 2 1780 1380 - 1135 6-φ17
900 2 1780 1380 - 1135 6-φ17
13C 2 1780 1380 - 1135 6-φ17
18C 3 1760 2360 - 1335 8-φ17
25C 4 1080 1430 1430 1335 12-φ17
36C 4 1280 1730 1730 1535 12-φ17
50C 5 1580 2360 2360 1535 14-φ17
(Front: with the door removed)
w1
w2
120
120
20
20
d
Cable
inlet
N-φ