Machine Protection
6-27
Timing Chart for Frequency Detection Operation
Related
constant
L4-01: Speed Agree Level
L4-02: Speed Agree Width
L4-03: Speed Agree Level +/−
L4-04: Speed Agree Width +/−
Fref/Fout
Agree
Fref/Fout Agree 1 Fref/Fout Agree 2
Fref/Set
Agree
Fref/Set Agree 1
(on at the following conditions during frequency
agree)
Fref/Set Agree 2 +/-
(on at the following conditions during frequency
agree)
Fre-
quency
Detection
Frequency (FOUT) Detection 1
(L4-01 > | Output frequency |)
Frequency (FOUT) Detection 3
(L4-03 > Output frequency)
Frequency (FOUT) Detection 2
(L4-01 < | Output frequency |)
Frequency (FOUT) Detection 4
(L4-01 < Output frequency)
L4-02
Off On
Frequency
reference
L4-02
Output frequency
or motor speed
Fref/Fout Agree 1
(Multi-function output setting = 2)
Off On
Frequency
reference
Output frequency
or motor speed
Fref/Fout Agree 2
L4-04
(Multi-function output setting = 13)
Off On
Output frequency
or motor speed
Fref/Set Agree 1
L4-02
L4-01
L4-01
L4-02
(Multi-function output setting = 3)
Off On
Output frequency
or motor speed
Fref/Set Agree 2
L4-04
L4-03
(Multi-function out
ut settin
= 14)
Freq. Detection 1
OffOn
Output frequency
or motor speed
L4-02
L4-02
L4-01
L4-01
(Multi-function output settin
= 4)
Freq. Detection 3
OffOn
Output frequency
or motor speed
L4-04
L4-03
(Multi-function output settin
= 15)
Freq. Detection 2
Off On
Output frequency
or motor speed
L4-02
L4-02
L4-01
L4-01
(Multi-function out
ut settin
= 5)
Freq. Detection 4
Off On
Output frequency
or motor speed
L4-04
L4-03
(Multi-function output settin
= 16)