Input Terminal Functions
6-47
Multi-Function Contact Inputs (H1-01 to H1-10)
Application Precautions
Jog frequencies using FJOG and RJOG commands are given priority over other frequency references.
When both FJOG command and RJOG commands are on for 500 ms or longer at the same time, the
Inverter stops according to the setting in b1-03 (stopping method selection).
Setting
Value
Function
Control Methods
Open-
loop
Vector
Flux
Vector
12 FJOG command (on: Forward run at jog frequency d1-17) Yes Yes
13 RJOG command (on: Reverse run at jog frequency d1-17) Yes Yes