Individual Functions
6-57
* When the control method is changed, the factory setting will change. The flux vector factory setting is given.
Setting Number of PG Pulses
Set the number of PG (Pulse Generator/Encoder) pulses in pulses/rotation. Set the number of A-phase or B-
phase pulses per 1 motor rotation in H7-01.
Matching PG Rotation Direction and Motor Rotation Direction
Constant H7-05 matches the PG rotation direction and the motor rotation direction. If the motor is rotating for-
wards, set whether it is A-phase driven or B-phase driven.
Fig 6.26 PG Rotation Direction Setting
H7-10
Excessive speed
deviation detection
level
Sets the speed deviation detec-
tion method.
Any speed deviation above the
H7-10 set level (set as a per-
centage of the maximum output
frequency) that continues for
the time set in H7-11 is
detected as a speed deviation.
Speed deviation is the differ-
ence between actual motor
speed and the reference com-
mand speed.
0 to 50 10% No No A 4A9H
PG Deviate Level
H7-11
Excessive speed
deviation detection
delay time
0 to
10.0
0.5 s No No A 4AAH
PG Deviate Time
H7-14
PG open-circuit
detection time
Used to set the PG disconnec-
tion detection time. PGO will
be detected if the detection time
continues beyond the set time.
0.0 to
10.0
3.0 s No No A 4ADH
PGO Detect Time
Constant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Operation
Control
Methods
MEMOBUS
Register
Open-
loop
Vector
Flux
Vector
Display
Inverter
Motor
Forward
Command
PG (encoder)
Pulse output
A-phase driven when set value = 0
B-phase driven when set value = 1
A-phase
B-phase
A-phase
B-phase
Example: Forward rotation of standard Yaskawa motor (PG used: Samtack (KK))
Forward
Command
Motor output axis rotates
counter-clockwise during
Inverter Forward Command.
Rotation
(CCW)
A-phase
B-phase
Yaskawa standard PG used is A-phase driven (CCW) when motor rotation is forward.