EasyManua.ls Logo

YASKAWA iQpump Micro

YASKAWA iQpump Micro
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
YASKAWA TOEP YAIQPM 01A iQpump Micro Quick Start Procedure
iQpump Micro
Quick Start Procedure
Page 26
of 31
11.1 Check the motor for proper direction and operation.
This test is performed solely from the digital operator. Apply power to the iQpump Micro after electrical connections are terminated and
protective covers are installed. At this point, DO NOT RUN THE MOTOR, The digital operator should display as shown in Figure 3.
LED Digital Operator (Standard)
Figure 3: LED Digital Operator (Standard)
Auto Mode Off
No alarm active
Hand Mode Off
5 00.0
11.2 Motor Rotation Test (Standard)
Refer to STEP 3, exchange any two
of the three output leads to the motor
(U/T1, V/T2 and W/T3).
Recheck motor direction after
the wiring change.
WARNING! Hazardous Voltage. Contact may cause electric shock or burn. Turn-off and lock-out system and facility power before
servicing. After the power has been turned OFF, wait at
least five minutes until the charge indicator extinguishes completely before touching
any wiring, circuit boards or components.
Press
and the
HAND
LED should be ON.
The motor should be operating in the correct direction of pump.
Press
on the digital operator; the display should read
on the digital operator; the display should read as in Figure 3.
Press to access Hand Speed. Use to change
HAND Speed value. Press to save value.
Digital operator
turned off.
NOTE: If the motor direction is not correct, de-energize the iQpump Micro and follow instructions below.
F40.00
11.3 Feedback Signal Check (Standard)
Verify the transducer feedback signal level on the digital operator display matches a mechanical pressure gauge..
FEEDBACK SIGNAL LEVEL
From HOME screen, press to access “FEEdb” screen.
FEEdb” will display for 2 seconds, then automatically change to display the
feedback signal level.
83.5
-
-
-
Verify Pump Rotation and Transducer Feedback
11