7 Concurrent I/O (Input/Output)
7.6 EtherNet/IP Status Warning
7-28
HW1485509
HW1485509
7.6 EtherNet/IP Status Warning
Problems with EtherNet/IP communication will be illuminated by a yellow
warning box surrounding the EtherNet/IP Status byte in the {Inputs} panel.
A help icon will appear containing descriptions for each bit in the EtherNet/
IP Status byte.
How To View the EtherNet/IP Status Byte
1. Go to {MENU} → {Program/Operate} → {I/O}.
2. Press {Inputs}.
3. Press {Settings}.
{Input Output Settings} panel will appear.
4. Under {Input Types to Display} check {EtherNet/IP Status}.
5. Click {X} in upper right of {Input Outputs Settings} panel.
{Input Output Settings} panel will close.
The {EtherNet/IP Status} input group will be in the left panel.
Fig. 7-21: EtherNet/IP Status Warning