11 Safety Function
11.3 Safety Logic Circuit
11-41
HW1485509
HW1485509
11.3.7.2 Correspondence between General Purpose Output Signals and Monitoring Signals
Table 11-15: Correspondence Between General Purpose Output Signals
and Monitoring Signals.
The following signals can be used only in the system where the safety I/O
expansion board (optional) is enabled. Then number of signals depends
on the circuit board.
Table 11-16: Correspondence Between General Purpose Output Signals
and Monitoring Signals with Safety IO Expansion Board
General-Purpose Safety Output
Signal
General-purpose safety output
monitoring signal (Feedback signal)
GSOUT1 S-GSEDM1
GSOUT2 S-GSEDM2
General-Purpose Safety Output
Signal
General-purpose safety output
monitoring signal (Feedback signal)
FSBOUT1 (XOUT1) S-XEDM1
FSBOUT2 (XOUT2) S-XEDM2
FSBOUT3 (XOUT3) S-XEDM3
FSBOUT4 (XOUT4) S-XEDM4
FSBOUT5 (XOUT5) S-XEDM5
FSBOUT6 (XOUT6) S-XEDM6
FSBOUT7 (XOUT7) S-XEDM7
FSBOUT8 (XOUT8) S-XEDM8
FSBOUT9 (XOUT9) S-XEDM9
FSBOUT10 (XOUT10) S-XEDM10
FSBOUT11 (XOUT11) S-XEDM11
FSBOUT12 (XOUT12) S-XEDM12
FSBOUT13 (XOUT13) S-XEDM13
FSBOUT14 (XOUT14) S-XEDM14
FSBOUT15 (XOUT15) S-XEDM15
FSBOUT16 (XOUT16) S-XEDM16