EasyManua.ls Logo

YASKAWA JZRCR-APP30-1 - 11.3.3.2 Selecting System and User Circuits; 11.3.3.3 Create New Safety Logic Circuit

YASKAWA JZRCR-APP30-1
493 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11 Safety Function
11.3 Safety Logic Circuit
11-17
HW1485509
HW1485509
11.3.3.2 Selecting System and User Circuits
By pressing Tab shown on the pendant and selecting the “User” or
“System”, the display can be switched between user and system safety
logic circuit.
SYSTEM: The system section of the safety logic circuit is shown.
USER: The user section of the safety logic circuit is shown.
11.3.3.3 Create New Safety Logic Circuit
To create new safety logic circuit, press {NEW LOGIC}.
A new line is created with one input relay and one output relay as shown
below.
Each line can have one or more input relays. Each line can have only one
output relay, and the same output signal cannot be set on multiple lines.
When the Safety Logic Circuit has been edited, the {Readback} shows on
top of the screen.
SUPPLE
-MENT
In certain cases, system section of the safety logic circuit
may not be defined at factory setting.