7 Concurrent I/O (Input/Output)
7.7 Block I/O
7-32
HW1485509
HW1485509
4. Press {PROCEED} after confirming the contents of the pop-up
window.
INFORM commands associated with the active Block I/O state will
be executed.
NOTE
During testing of a Block I/O state, its execution can be
canceled.
This may be necessary if the Block I/O commands
contain Timer(s) that are set to long durations.
While Block I/O is executing, other pendant functions
are not accessible
On the Block I/O screen, the user can also view:
a list of all Block I/O settings
view & compare details for selected Block I/O states
create a new Block I/O setting
delete an existing Block I/O setting