11 UL Standards
EN 48 YASKAWA Europe TOEP C710616 92D AC Drive L1000H Quick Start Guide
Note: Use crimp insulated terminals or insulated tubing for wiring these connections. Wires should have a continuous maximum allowable
temperature of 75 C 600 V UL approved vinyl sheathed insulation. Ambient temperature should not exceed 40 C.
Closed-Loop Crimp Terminal Recommendations
YASKAWA recommends using closed-loop crimp terminals on all drive models. UL approval requires the use of crimp
terminals when wiring the drive main circuit terminals on models 40045 to 40150. Use only crimping tools as
specified by the crimp terminal manufacturer. YASKAWA recommends crimp terminals made by JST and Tokyo DIP (or
equivalent) for the insulation cap.
The table below matches the wire gauges and terminal screw sizes with YASKAWA - recommended crimp terminals,
tools, and insulation caps. Refer to the appropriate Wire Gauge and Torque Specifications table for the wire gauge and
screw size for your drive model. Place orders with a YASKAWA representatives the YASKAWA sales department.
40075
<4>
R/L1, S/L2,
T/L3
25 16 to 50 30 22 to 60 2 3 to 1/0
M8
9 to 11
(79.7 to 97.4)
U/T1, V/T2,
W/T3
25 25 to 50 30 22 to 60 2 3 to 1/0
–, +1 – 25 to 50 38 30 to 60 – 3 to 1/0
+3 – 16 to 50 22 14 to 60 – 6 to 1/0
16 16 to 25 22 14 to 22 4 6 to 4
40091
<4>
R/L1, S/L2,
T/L3
35 25 to 50 38 30 to 60 1/0 2 to 1/0
M8
9 to 11
(79.7 to 97.4)
U/T1, V/T2,
W/T3
35 25 to 50 38 30 to 60 1 2 to 1/0
–, +1 – 25 to 50 60 30 to 60 – 3 to 1/0
+3 – 25 to 50 30 22 to 60 – 4 to 1/0
16 16 to 25 22 14 to 22 4 6 to 4
40112
<4>
R/L1, S/L2,
T/L3
50 35 to 95 60 38 to 100 3/0 1/0 to 4/0
M10
18 to 23
(159 to 204)
U/T1, V/T2,
W/T3
50 35 to 95 60 60 to 100 2/0 1/0 to 4/0
–, +1 – 50 to 95 100 60 to 100 – 1/0 to 4/0
+3 – 25 to 95 50 30 to 100 – 3 to 4/0
25 25 22 22 4 4
40150
<4>
R/L1, S/L2,
T/L3
70 50 to 95 80 60 to 100 4/0 3/0 to 4/0
M10
18 to 23
(159 to 204)
U/T1, V/T2,
W/T3
70 70 to 95 80 80 to 100 4/0 3/0 to 4/0
–, +1 – 35 to 95 50 2P 50 to 100 – 1 to 4/0
+3 – 50 to 95 60 50 to 100 – 1/0 to 4/0
35 25 to 35 22 22 to 30 4 4 to 2
<1> Gauges listed here are for use in Europe and China.
<2> Gauges listed here are for use in Asia except for China.
<3> Gauges listed here are for use in the United States.
<4> Drive models CIMR-L40045 to 40150 require the use of closed-loop crimp terminals for UL/cUL compliance. Use only the tools
recommended by the terminal manufacturer for crimping.
Wire Gauge
Terminal
Screws
Crimp Terminal
Model Number
Tool
Insulation Cap
Model No.
Code <1>
Machine No. Die Jaw
14 AWG M4 R2-4 YA-4 AD-900 TP-003 100-054-028
12 / 10 AWG
M4 R5.5-4 YA-4 AD-900 TP-005 100-054-029
M5 R5.5-5 YA-4 AD-900 TP-005 100-054-030
8 AWG
M4 8-4 YA-4 AD-901 TP-008 100-054-031
M5 R8-5 YA-4 AD-901 TP-008 100-054-032
Model
CIMR-L
Terminal
For Europe and China <1> For Asia <2> For U.S.A <3>
Screw
Size
Tightening
Torque
Nm (lb.in.)
Recommended
Gauge
mm
2
Applicable
Gauge
mm
2
Recommended
Gauge
mm
2
Applicable
Gauge
mm
2
Recommended
Gauge
AWG, kcmil
Applicable
Gauge
AWG, kcmil