9 Maintenance and Inspection
9.2 Notes on Maintenance Procedures
9-6
177010-1CD
HW1483759
MH215 II
Fig. 9-3: Battery Connection
1. Turn OFF the DX200 main power supply.
2. Remove the plate fixing screws and the plate on the connector base,
then pull the battery pack out to replace it with the new one.
3. Remove the battery pack from the battery holder.
4. Connect the new battery pack to the unoccupied connector on the
board.
5. Remove the old battery pack from the board.
6. Mount the new battery pack to the holder.
7. Reinstall the plate.
Remove the old battery pack after connecting the new one
so that the encoder absolute data does not disappear.
Do not allow plate to pinch the cables when reinstalling the
plate.
See replacing step 5.
Board
Connector
See replacing step 4.
New battery pack
Battery pack
before replacement
(T
ype: SGDR-EFBA02A)
(HW0470360-A)