6 MECHATROLINK II Communications
6.3.8 Start Synchronous Communications (SYNC_SET: 0DH)
6-14
6.3.8 Start Synchronous Communications (SYNC_SET: 0DH)
Byte SYNC_SET Description
Command Response
1 0DH 0DH Processing
classifications
Network com-
mand group
Synchronization
classifications
Asynchronous
2 ALARM Processing time Transmission
cycle or more
Subcommand Cannot be used
3STATUS• Starts synchronous communications. Switches from phase 2 to phase 3.
• Processing is completed at the WDT changing edge.
However, if WDT errors are being masked by parameter Pn800.0, processing
is completed when this command is received.
During phase 1, a MECHATROLINK II command warning1 (A.95A) will
occur and the command will be ignored.
• During phase 3, the command will be ignored (without a warning).
The SERVOPACK will change to Servo OFF if this command is received.
• At the occurrence of the following alarms, this command must be transmitted
to restart synchronous communications.
- MECHATROLINK II Synchronization Error (A.E50)
- MECHATROLINK II Synchronization Failure (A.E51)
- MECHATROLINK II Communications Error (A.E60)
- MECHATROLINK II Transmission Cycle Error (A.E61)