6 MECHATROLINK II Communications
6.3.14 Apply Brake (BRK_ON: 21H)
6-20
6.3.14 Apply Brake (BRK_ON: 21H)
• Related Parameter
Byte BRK_ON Description
Command Response
1 21H 21H Processing
classifications
Control com-
mand group
Synchronization
classifications
Asynchronous
2 ALARM Processing time Within communi-
cations cycle
Subcommand Cannot be used.
3STATUS
Applies brake.
This command is enabled when the parameter Pn50F.2 is not
set to 0. This command is enabled only while the servo is OFF.
• Can be used during phases 2 and 3.
• A warning will occur and the command will be ignored in the following cases.
- During phase 1: MECHATROLINK II command warning1 (A.95A)
- If Pn50F.2 is set to 0: Command setting warning 3 (A.95C)
Brake signal output timing
4
5 MONITOR 1
6
7
8
9 MONITOR 2
10
11
12
13 SEL_MON 1/2 SEL_MON 1/2
14 IO_MON
15
16 WDT RWDT
Pn No. Description
Pn50F.2 /BK signal allocation
Within 3 ms