EasyManua.ls Logo

YASKAWA SGDS Sigma III Series - 3 SERVOPACK Specifications and Dimensional Drawings; SERVOPACK Ratings and Specifications

YASKAWA SGDS Sigma III Series
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 SERVOPACK Specifications and Dimensional Drawings
3-2
3.1 SERVOPACK Ratings and Specifications
SERVOPACK Model SGDS- A5 01 02 04 08 10 15 20 30
Basic Specifications
Max. Applicable Servomotor Capacity
[kW]
0.05 0.1 0.2 0.4 0.75 1.0 1.5 2.0 3.0
100 V Continuous Output Current
[Arms]
0.66 0.91 2.1 2.8 −−−
Max. Output Current [Arms]
2.1 2.8 6.5 8.5 −−−
200 V Continuous Output Current
[Arms]
0.66 0.91 2.1 2.8 5.5 7.6 10.7 16.7 23.8
Max. Output Current [Arms]
2.1 2.8 6.5 8.5 16.9 17.0 28 42 56
Input Power
Supply
SERVOPACK
Capacity Range
for 100/200 V
Single-phase 100 VAC
Single-phase 200 VAC Single-
phase
200
VA C
−−
Three-phase 200 VAC
200 V Main Circuit Three-phase (or single-phase) 200 to 230 VAC +10 to -15%, 50/60 Hz
Control Circuit Single-phase 200 to 230 VAC +10 to -15%, 50/60 Hz
100 V Main Circuit Single-phase 100 to 115 VAC +10 to -15%, 50/60 Hz
Control Circuit Single-phase 100 to 115 VAC +10 to -15%, 50/60 Hz
Control Method Single or three-phase full-wave rectification IGBT-PWM (sine-wave driven)
Feedback Serial encoder: 17-bit (incremental/absolute)
Operating
Conditions
Ambient/Storage
Temperature
0 to +55°C/ -20 to +85°C
Ambient/Storage
Humidity
90% RH or less (with no condensation)
Vibration/Shock
Resistance
4.9 m/s
2
/ 19.6 m/s
2
Configuration Base-mounted (Rack mounting available as an option)
Performance Speed Control Range 1:5000 (The lowest speed of the speed control range is the speed at
which the servomotor will not stop with a rated torque load.)
Speed
Regu-
lation
Load
Regulation
0 to 100% load: 0.01% max. (at rated speed)
Voltage
Regulation
Rated voltage ±10%: 0% (at rated speed)
Temperature
Regulation
25 ± 25
°C: ±0.1% max. (at rated speed)
Frequency
Characteristics
600 Hz (at J
L
= J
M
)
Torque Control
Tolerance
(Repeatability)
±1%
Soft Start Time Setting 0 to 10 s (Can be set individually for acceleration and deceleration.)

Table of Contents

Related product manuals