6 MECHATROLINK II Communications
6.4.5 Read Non-volatile Parameter (PPRM_RD: 1CH)
6-46
6.4.5 Read Non-volatile Parameter (PPRM_RD: 1CH)
6.4.6 Write Non-volatile Parameter (PPRM_WR: 1CH)
Byte ALM_RD Description
Command Response Processing
classifications
Data communica-
tions command
group
Processing time Within 200 ms
17 1BH 1BH This command is not supported.
18 Substatus
19 NO NO
20
21 SIZE SIZE
22 PARAMETER
23
24
25
26
27
28
29
Byte PPRM_WR Description
Command Response Processing
classifications
Data communica-
tions command
group
Processing time Within 200 ms
17 1CH 1CH • Writes the parameters. This command has the same function as the main
command PPRM_WR.
This command can be used only with the following main commands:
NOP, ID-RD, HOLD, LTMOD_ON/OFF, SMON, SV_ON/OFF,
INTERPOLATE, POSING, FEED, LATCH, EX_POSING, ZRET, VELCTRL,
TRQCTRL
18 Substatus
19 NO NO
20
21 SIZE SIZE
22 PARAMETER PARAMETER
23
24
25
26
27
28
29