11.1 Servomotor Capacity Selection Examples
11-9
If the energy consumed by load loss (in step 2 above) is unknown, then perform the calculation using E
L
= 0.
When the operation period in regeneration mode is continuous, add the following items to the above
calculation procedure in order to find the required capacity (W) for the regenerative resistor.
Energy for continuous regeneration mode operation period: E
G
(joules)
Energy consumed by regenerative resistor: E
K
= E
S
- (E
L
+ E
M
+ E
C
) + E
G
Required capacity of regenerative resistor: W
K
= E
K
/ (0.2 × T)
Here, E
G
= (2π/60) N
MG
T
G
t
G
T
G
: Servomotors generated torque (N·m) in continuous regeneration mode operation period
N
MG
:Servomotor rotation speed (RPM) for same operation period as above
t
G
:Same operation period (s) as above
(b) Servomotor Winding Resistance Loss
The following diagrams show the relationship, for each servomotor, between the servomotors generated
torque and the winding resistance loss.
SGMAH Servomotor, 200V SGMAH Servomotor, 100V
SGMPH Servomotor, 200V SGMPH Servomotor, 100V
200
250
150
100
50
0
0 100 200 300
300
Torque (%)
(W)
SGMAH-
04A
08A
01A, 02A
A5A
A3A
Loss
200
180
160
140
120
100
80
60
40
20
0
0 100 200 300
Torque (%)
SGMAH-
01B
02B
A5B
A3B
(W)
Loss
200
250
150
100
50
0
0 100 200 300
300
Torque (%)
(W)
SGMPH-
15A
08A
04A
01A
02A
Loss
160
140
120
100
80
60
40
20
0
0 100 200 30
0
Torque (%)
(W)
SGMPH-
02B
01B
Loss

Table of Contents