Individual Functions
6-91
Related Constants
* Set H5-01 to 0 to disable Inverter responses to MEMOBUS communications.
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vec-
tor
Open
Loop
Vector
2
b1-01
Reference
selection
Set the frequency reference input
method.
0: Digital Operator
1: Control circuit terminal (analog
input)
2: MEMOBUS communications
3: Option board
4: Pulse train input
0 to 4 1 No QQQQQ
Reference
Source
b1-02
Operation
method selec-
tion
Set the Run Command input
method.
0: Digital Operator
1: Control circuit terminal
(sequence input)
2: MEMOBUS communications
3: Option board
0 to 3 1 No QQQQQ
Run Source
H5-01
Slave address
Set the Inverter's slave address.
0 to 20
*
1FH No AAAAA
Serial Comm
Adr
H5-02
Communica-
tion speed
selection
Set the baud rate for 6CN
MEMOBUS communications.
0: 1200 bps
1: 2400 bps
2: 4800 bps
3: 9600 bps
4: 19200 bps
0 to 4 3 No AAAAA
Serial Baud
Rate
H5-03
Communica-
tion parity
selection
Set the parity for 6CN MEMOBUS
communications.
0: No parity
1: Even parity
2: Odd parity
0 to 2 0 No AAAAA
Serial Com
Sel
H5-04
Stopping
method after
communica-
tion error
Set the stopping method for com-
munications errors.
0: Deceleration to stop using
deceleration time in C1-02
1: Coast to stop
2: Emergency stop using
deceleration time in C1-09
3: Continue operation
0 to 3 3 No AAAAA
Serial Fault
Sel
H5-05
Communica-
tion error
detection
selection
Set whether or not a communica-
tions timeout is to be detected as a
communications error.
0: Do not detect.
1: Detect
0 or 1 1 No AAAAA
Serial Flt Dtct
H5-06
Send wait
time
Set the time from the Inverter
receiving data to when the Inverter
starts to send.
5 to 65 5 ms No A A A A A
Transmit
WaitTIM
H5-07
RTS control
ON/OFF
Select to enable or disable RTS
control.
0: Disabled (RTS is always ON)
1: Enabled (RTS turns ON only
when sending)
0 or 1 1 No AAAAA
RTS Control
Sel

Table of Contents