Wiring Examples
10-19
10
îš‹ Using Contact and Open Collector Outputs
This example shows wiring for contact outputs and open collector outputs.
The following example is for the CIMR-G7A25P5 (200 V Class Inverter for 5.5 kW).
Fig 10.14
Inverter
U/T1
V/T2
W/T3
IM
Ground
MA
MB
MC
Error contact output
P2
PC
Open collector 1
Multi-function
open collector output
48 VDC 50 mA max.
P1
(Default: zero speed)
M1
M2
Multi-function contact output
(Default: RUN)
T/L3
S/L2
R/L1
3-phase power
M
CC
B
T
S
R
FM
A
M
Multi-function analog output 1
A
C
E
(
G
)
-10 to +10 V 2 mA
A
M
FM
Default: Output frequency,
0 to +10 V
Default: Ouput current,
0 to +10 V
-10 to +10 V 2 mA
Multi-function analog output 2
Frequency meter scale adjustment resistor
20 k
B2B1
Ammeter scale adjustment resistor
20 k
Motor
Sequence external power
supply
Surge
absorber
250 VAC max.
30 VDC max.
Flywheel
diode
48 VDC max.
48 VDC max.
Sequence
(Default: Freq agree)
250 VAC, 10 mA min. 1 A max.
30 VDC, 10 mA min. 1 A max.
250 VAC, 10 mA min. 1 A max.
30 VDC, 10 mA min. 1 A max.
E
(
G
)
+ 1 + 2
-
Flywheel
diode
Flywheel
diode
Open collector 2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA Varispeed CIMR-G7A and is the answer not in the manual?

YASKAWA Varispeed CIMR-G7A Specifications

General IconGeneral
BrandYASKAWA
ModelVarispeed CIMR-G7A
CategoryInverter
LanguageEnglish

Related product manuals