6-146
îš‹ Copying Constants
The Digital Operator can perform the following three functions using the built-in EEPROM (non-volatile
memory).
• Store Inverter constant set values in the Digital Operator (READ)
• Write constant set values stored in the Digital Operator to the Inverter (COPY)
• Compare constant set values stored in the Digital Operator with Inverter constants (VERIFY)
Related Constants
Con-
stant
Number
Name
Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
Display
V/f
V/f
with
PG
Open
Loop
Vector
1
Flux
Vec-
tor
Open
Loop
Vector
2
o3-01
Copy function
selection
0: Normal operation
1: READ (Inverter to Operator)
2: COPY (Operator to Inverter)
3: Verify (compare)
0 to 3 0 NoAAAAA
Copy Function
Sel
o3-02
Read permitted
selection
0: Read prohibited
1: Read permitted
0 or 1 0 No A A A A A