Administrator’s Guide for SIP-T2 Series/T4 Series/T5 Series/CP920 IP Phones
157
Sending Volume Configuration
You can configure the sending volume of currently engaged audio devices (handset, speakerphone or headset)
when the phone is in use.
The following table lists the parameters you can use to configure the sending volume.
Parameter
voice.handfree_send
[1]
<y0000000000xx>.cfg
Description
It configures the sending volume of the speaker.
Note: We recommend that you modify this parameter cautiously. An unsuitable value may render the
voice quality bad.
Permitted
Values
Integer from -50 to 50
Default
0
Web UI
Features > Audio > Handfree Send Volume (-50~50)
Parameter
voice.handfree.autoreset_spk_vol <y0000000000xx>.cfg
Description
It configures the speaker's volume level during a call.
Permitted
Values
0-The speakerphone volume at the end of a call persists between calls.
1 to 15-The speakerphone volume does not persist between calls, and resets to this specified level
each new call.
Default
0
Parameter
voice.handset_send
[1]
<y0000000000xx>.cfg
Description
It configures the sending volume of the handset.
Note: We recommend that you modify this parameter cautiously. An unsuitable value may render the
voice quality bad.
Permitted
Values
Integer from -50 to 50
Default
0
Supported
Devices
All phones except CP920
Web UI
Features > Audio > Handset Send Volume (-50~50)
Parameter
voice.handset.autoreset_spk_vol <y0000000000xx>.cfg
Description
It configures the handset's volume level during a call.
Permitted
Values
0-The handset volume at the end of a call persists between calls.
1 to 15-The handset volume does not persist between calls, and resets to this specified level each
new call.
Default
0
Supported
Devices
All phones except CP920
Parameter
voice.headset_send
[1]
<y0000000000xx>.cfg
Description
It configures the sending volume of the headset.
Note: We recommend that you modify this parameter cautiously. An unsuitable value may render the
voice quality bad.

Table of Contents

Other manuals for Yealink SIP-T40G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yealink SIP-T40G and is the answer not in the manual?

Yealink SIP-T40G Specifications

General IconGeneral
MountingDesk/Wall
Handset typeWired handset
Product typeIP Phone
Product colorBlack
Wall mountableYes
Wi-FiNo
Security algorithmsAES, HTTPS, SSL/TLS
Networking standardsIEEE 802.3af
Ethernet LAN interface typeGigabit Ethernet
Supported network protocolsFTP, TFTP, HTTP, HTTPS
Voice codecsG.711, G.711a, G.711u, G.722, G.726, G.729ab
RJ-11 ports quantity1
Ethernet LAN (RJ-45) ports2
AC adapter input voltage100 - 240 V
AC adapter output current0.6 A
AC adapter output voltage5 V
Power consumption (typical)1.6 W
CertificationCE, FCC, ISO 9001
Operating temperature (T-T)-10 - 50 °C
Operating relative humidity (H-H)10 - 90 %
Volume controlDigital
Display diagonal2.3 \
Display resolution132 x 64 pixels
Lines quantity3 lines
Phonebook capacity1000 entries
Number of VoIP accounts3
Number of handles included1 pc(s)
Weight and Dimensions IconWeight and Dimensions
Depth175 mm
Width212 mm
Height54 mm

Related product manuals