Troubleshooting Methods
536
(1) If the local log files are configured to be uploaded to the server by the parameter “static.auto_pro-
vision.local_log.backup.enable”, the phone will clear all the local log files on the phone once suc-
cessfully backing up.
(2) If “static.auto_provision.local_log.backup.enable is set to 0 (Disabled), the phone will erase half of
the logs from the oldest log information on the phone.
Example:
static.local_log.max_file_size = 1024
Permitted
Values
T40P/T40G/T23P/T23G/T21(P) E2/T19(P) E2:
Integer from 256 to 1024
Other phones:
Integer from 256 to 2048
Default
T40P/T40G/T23P/T23G/T21(P) E2/T19(P) E2:
256
Other phones:
1024
Web UI
T40P/T40G/T23P/T23G/T21(P) E2/T19(P) E2:
Settings > Configuration > Max Log File Size (256-1024KB)
Other phones:
Settings > Configuration > Max Log File Size (256-2048KB)
Parameter
static.auto_provision.local_log.backup.enable <y0000000000xx>.cfg
Description
It enables or disables the phone to upload the local log files to the provisioning server or a specific
server.
Note: The upload path is configured by the parameter “static.auto_provision.local_log.backup.path”.
Permitted
Values
0-Disabled
1-Enabled, the phone will upload the local log files to the provisioning server or the specific server to
back up these files when one of the following happens:
- Auto provisioning is triggered;
- The size of the local log files reaches the maximum configured by the parameter “static.local_
log.max_file_size”;
- It’s time to upload local log files according to the upload period configured by the parameter “stat-
ic.auto_provision.local_log.backup.upload_period”.
Default
0
Parameter
static.auto_provision.local_log.backup.upload_period <y0000000000xx>.cfg
Description
It configures the period (in seconds) of the local log files uploads to the provisioning server or a spe-
cific server.
Note: It works only if “static.auto_provision.local_log.backup.enable is set to 1 (Enabled).
Permitted
Values
Integer from 30 to 86400
Default
30
Parameter
static.auto_provision.local_log.backup.path <y0000000000xx>.cfg
Description
It configures the upload path of the local log files.

Table of Contents

Other manuals for Yealink SIP-T40G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yealink SIP-T40G and is the answer not in the manual?

Yealink SIP-T40G Specifications

General IconGeneral
MountingDesk/Wall
Handset typeWired handset
Product typeIP Phone
Product colorBlack
Wall mountableYes
Wi-FiNo
Security algorithmsAES, HTTPS, SSL/TLS
Networking standardsIEEE 802.3af
Ethernet LAN interface typeGigabit Ethernet
Supported network protocolsFTP, TFTP, HTTP, HTTPS
Voice codecsG.711, G.711a, G.711u, G.722, G.726, G.729ab
RJ-11 ports quantity1
Ethernet LAN (RJ-45) ports2
AC adapter input voltage100 - 240 V
AC adapter output current0.6 A
AC adapter output voltage5 V
Power consumption (typical)1.6 W
CertificationCE, FCC, ISO 9001
Operating temperature (T-T)-10 - 50 °C
Operating relative humidity (H-H)10 - 90 %
Volume controlDigital
Display diagonal2.3 \
Display resolution132 x 64 pixels
Lines quantity3 lines
Phonebook capacity1000 entries
Number of VoIP accounts3
Number of handles included1 pc(s)
Weight and Dimensions IconWeight and Dimensions
Depth175 mm
Width212 mm
Height54 mm

Related product manuals